Skip to main content Skip to search Skip to main navigation

BOD measuring system OxiTop®-IDS for determination of aerobic degradation, Set 6

Filter products

Product information "BOD measuring system OxiTop®-IDS for determination of aerobic degradation, Set 6"

These tests quantify the biological degradability of chemicals.
With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.

  • Respirometric degradability tests according to OECD 301F/DIN EN ISO 9408
  • Versatile measurement by using the BOD special mode
  • Measurement duration selectable (0.5 hours to 180 days)
  • Bluetooth® connectivity
  • Direct calculation of all results in the meter
  • Representation of curves for monitoring
  • Parallel measurement of different examinations and methods
  • Export to data acquisition programs


Please order CO2 absorber NHP 600 (9.303 403) separately.
The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.

  • OxiTop®-IDS Set 6 also for BOD self-monitoring measurements


Scope of supply: 6 x OxiTop®-IDS measuring heads, 6 x bottles PF600 (510 ml), 6 x rubber sleeves, nitrification inhibitor, overflow measuring flask, 6 x magnetic stirring bars, stirring bar retriever, stirring platform IS 6

Manufacturer Article Number: 209711
Max. measured value: 4000 mg/l
Max. pressure: 1250 hPa
Max. voltage: 240 V
Measured range: 0 ... 4,000 mg/l
Measuring time: 180 d
Min. measured value: 0 mg/l
Min. pressure: 500 hPa
Min. voltage: 100 V
No. of measuring positions: 6
Nominal volume bottle: 510 ml
Power supply: 100 ... 240 V, 50/60 Hz
Power supply frequency: 50/60 Hz
Pressure: 500 ... 1,250 hPa
Type: OxiTop®-IDS Set 6
Type of auxiliary energy: Battery/mains connection
Skip product gallery

Accessories

Multiparameter meter MultiLine® 3620 IDS Set WL
Professional digital multiparameter meters for mobile measurement, wireless preparation, data logger manually or automatically (timed). Easy to clean with a soft brush under water jet. The Multi 3620 IDS with two universal measurement channels is suitable for all WTW IDS pH, ORP, dissolved oxygen sensors, conductivity cells and turbidity sensors, whether connected to cable or wireless. Documentation of meter and sensor data. User control over MultiLab® users. With USB-A and Mini USB-B interface and colour display.Also for controlling OxiTop® IDS.Scope of supply: Instrument, short manual, CD-ROM, rechargeable batteries, driver software for USB, cable, power supply, protection SM Pro, IDS WLM-M module

€0.00*
Stirring platforms OxiTop® for BOD measurement
These Stirring platforms have been specially developed for BOD measurement with the OxiTop® system. Software-controlled speed regulation prevents the magnetic stirrer bar from getting caught or wobbling. The speed is selected so that an optimal gas exchange with the sample takes place. The stirrer is maintenance-free and non-wearing as it contains no moving parts.The IS 6-Var model has been specially developed for use with large measuring vessels and has space for 6 measuring vessels. Its outer dimensions are identical to those of the IS 12. Speed 180 to 450 rpm.

€0.00*
Wireless module IDS WLM-M for WTW® measuring instruments
Wireless module for connecting to MultiLine® 3310/3510/36x0 IDS, inoLab® Multi IDS and MonoLine. Connects up to three sensors at the same time (depends on meter capabilities). Also for operation of OxiTop®-IDS.

€0.00*
Wireless measuring heads OxiTop® IDS
OxiTop®-IDS wireless measuring head with Bluetooth® LE technology for operation with Multi 3620 IDS or Multi 3630 IDS. For routine BOD readings also operable without IDS multiparameter instrument. OxiTop®-IDS/B with enhanced pressure range up to 1500 hPa and H2S resistant pressure sensor for biogas measurement.Memory for 360 measuring points3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionFor routine BOD readings measurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsIntermediate values available

€0.00*
Skip product gallery

Other customers also bought

BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology
For the measurement of anaerobic degradability with OxiTop®-IDS/B measuring heads. The main application for these sets is the testing of fermentability of biological waste for biogas plants acc. to VDI 4630. The yield of methane can be measured in the pressure mode.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Convenient and safe operation within an extended pressure range of up to 1500 hPaPressure range excess warningCorrosion-proof head even in presence of H2SBluetooth® connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsScope of supply:OxiTop®-IDS AN6: 6 x OxiTop®-IDS/B measuring heads, 6 sample bottles MF45/1000 (1000 ml), nitrification inhibitor, 6 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS 6-VarOxiTop®-IDS AN12: 12 x OxiTop®-IDS/B measuring heads, 12 sample bottles MF45/250 (250 ml), nitrification inhibitor, 12 x magnetic stirring bars, stirring bar retriever, 1 stirring platform IS-12Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.

€0.00*
BOD Measuring system OxiTop®-IDS B6 for determination of soil respiration
Respirometric measuring system for 6 measuring heads for determination of aerobic soil respiration, OxiTop®-IDS B6M-2.5 acc. to AT4 guideline. These sets are suitable for forecast, survey and monitoring of clean-up operations as well as measurement of bio-degradation of pesticides, fungicides, insecticides and fertilizers for example.With the proven Bluetooth® connectivity and the convenient operation via MultiLine® multi parameter instrument Multi 3620 IDS or Multi 3630 IDS. Using a Multi 3620 IDS or Multi 3630 IDS in BOD special mode the BOD measuring range extends to 400000 mg/l. For an already existing Multi 3620 or 3630 IDS, a firmware update is sufficient. Herewith beneath the OxiTop® applications also measurement of pH, conductivity, solved oxygen and turbidity are available. All heads can be used independently for routine BOD measurements from 1 to 7 days.Bluetooth® connectivityDirect calculation of all results in the meterRepresentation of curves for monitoringParallel measurement of different examinations and methodsExport to data acquisition programsMeasurement duration selectable (0.5 hours to 180 days)Please order CO2 absorber NHP 600 (9.303 403) separately.The IDS multi parameter measuring instruments Multi 3620 IDS Set WL or Multi 3630 IDS Set WL are required. Please order separately.Scope of supply: 6 measuring heads, 6 sample bottles PF45/500 (500 ml), 6 adapters OxiTop® AD/SK

€0.00*
BOD measurement system OxiTop®-i IS 6 / 12
Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.No dilution of the sample requiredDirect reading of the BOD, the time course and the intermediate values on the graphical display of the measuring headsInput of the used sample volume directly at the measuring headMonitoring time between 1 and 7 daysPermanent display of the current status at each measuring headColoured measuring heads with adjustable, numerical sample identificationScope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12An incubator is required to operate the OxiTop®-i IS. Please order separately.

€0.00*