                        Product information "BOD measurement system OxiTop®-i IS 6 / 12"
                        Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.
Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12
An incubator is required to operate the OxiTop®-i IS. Please order separately.
Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.
Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12
An incubator is required to operate the OxiTop®-i IS. Please order separately.
                    
                
                                                                - No dilution of the sample required
- Direct reading of the BOD, the time course and the intermediate values on the graphical display of the measuring heads
- Input of the used sample volume directly at the measuring head
- Monitoring time between 1 and 7 days
- Permanent display of the current status at each measuring head
- Coloured measuring heads with adjustable, numerical sample identification
Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12
An incubator is required to operate the OxiTop®-i IS. Please order separately.
- No dilution of the sample required
- Direct reading of the BOD, the time course and the intermediate values on the graphical display of the measuring heads
- Input of the used sample volume directly at the measuring head
- Monitoring time between 1 and 7 days
- Permanent display of the current status at each measuring head
- Coloured measuring heads with adjustable, numerical sample identification
Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12
An incubator is required to operate the OxiTop®-i IS. Please order separately.
| Hazardous Substance Data | |
| GHS | |
| H-Satz | H290, H314 | 
| P-Satz | P280, P301+P330+P331, P305+P351+P338 | 
| Battery/rechargeable battery: | 1 x CR2450 | 
|---|---|
| Designation IEC: | CR2450 | 
| GHS: | GHS05 | 
| Manufacturer Article Number: | 208262 | 
| Max. measured value: | 4000 mg/l | 
| Max. pressure: | 1250 hPa | 
| Max. voltage: | 240 V | 
| Measured range: | 0 ... 4,000 mg/l | 
| Measuring time: | 7 d | 
| Min. measured value: | 0 mg/l | 
| Min. pressure: | 500 hPa | 
| Min. voltage: | 100 V | 
| No. of batteries/rechargeable batteries: | 1 | 
| No. of measuring positions: | 12 | 
| Plug type: | Universal | 
| Power supply: | 100 ... 240 V, 50/60 Hz | 
| Power supply frequency: | 50/60 Hz | 
| Pressure: | 500 ... 1,250 hPa | 
| Type: | OxiTop®-i IS 12 | 
| Type of auxiliary energy: | Battery/mains connection | 
 
                                                                 
                                                                                                                                                                                                                                                                         
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                