- General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and Microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Life Sciences
- Chromatography
- Cleanroom
- About Us
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
For installation of capillaries at exhaust filter connection of b.safe Waste Caps. The adapter made of PE-EX is conductive.
Space problems in the lab? Use the adapters for the exhaust filter to gain more free space. Attach the exhaust filter in any position - perfect when dealing with lower installation heights.
Air valves prevent the formation of vacuum in HPLC bottles.PTFE membrane1/4"-28 thread portWith timestrip sticker
Thread size UNF 1/4" 28GLuer Lock adapterPTFE FilterValve membrane blocks vapours and opens at negative pressureIt is recommended to replace the valve every 6 monthsWith change indicator and labelling field for timely change
Red/yellow. With connecting thread UNF ¼" 28G. Filter membrane made of PTFE/PP with a porosity of 1 µm and integrated non-return valve made of silicone. With service life indicator.
The air valve blocks harmful vapours and ensures safe pressure equalisation in the storage tanks. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.With filter membraneLuer-Lock connectionChange indicator
The integrated non-return valve avoids evaporation of solvents and lets flow ambient air into the bottle in case of vacuum. The upstream PP membrane restrains pollutant particles and other contaminations from outside.Free from polyhaloolefinsLid with aeration opening and Luerlock connectorClip-on service life indicator
Aluminium oxides produced by dehydration of different aluminium hydroxides, e. g. hydrargillite between 400 and 500°C, activity grade I, particle size 50 to 200µm, specific surface (BET) ~ 130m²/g.
Grain size 5 µm, pore dia. 100 Å. Octadecyl phase, endcapped, 15 % C.To connect ec-columns with ec pre columns a on-column ec pre column holder is reqiured!
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fittings (PFA), air valve
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fitting (PFA), air valve
Screw caps, with flat, freely movable insert made of PTFE, for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator. The connections are lateral, at a 90° angle to the bottle thread.Scope of supply:fittings (PFA), blind fitting (PFA), air valve
Screw caps, with freely movable insert made of PTFE. With PFA fittings for capillaries with O.D. 3,2 mm (UNF 1/4"), PTFE fittings preparative for tubing with O.D. 6,35 mm (thread NPT 1/8"), and an air valve with service life indicator.Scope of supply:fitting (PFA, Ø 3,2 mm), fitting (PTFE, Ø 6,35 mm), blind fittings (PTFE), air valve
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator. All capillary connectors with integrated stopcock and additional capillary connector on the bottom side of the lid.Scope of supply:connections with stopcocks, fittings top (PFA), fittings bottom (PFA), air valve
Screw caps, with freely movable insert made of PP, with female threads UNF ¼" 28G, for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve. Free from polyhaloolefins.Insert made of PPFittings made of PEIdeal for PFAS analysisDIN 38407-42 and DIN 38414-14 compliantEU Directive 202/2184 compliantScope of supply:Cap, fittings (PE), blind fittings (PE), air valve with service life indicator
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fittings (PFA), air valve
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fittings (PFA), air valve
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fittings (PFA), air valve
Screw cap with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) or a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fittings (PFA), air valve
Screw caps, with freely movable insert made of PTFE, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator. All capillary connectors with integrated stopcock and additional capillary connector on the bottom side of the lid.Scope of supply:connection with stopcock, fitting top (PFA), fitting bottom (PFA), air valve
Caps with ground joint cone NS 29/32, with female threads UNF ¼", for connecting capillary tubing (O.D. 3.2 mm) and a b.safe air valve with service life indicator.Scope of supply:fittings (PFA), blind fitting (PFA), air valve, locking nut (PP)
Screw cap with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).The Waste Caps are supplied with a permanently mounted cable (400 mm length) to connect the b.safe display for level control. The red indicator pin on the Waste Caps enables visual monitoring of the fill level.Scope of supply: fittings (UNF 1/4“), blind fitting (UNF 1/4“), hose olive (NPT 1/8")
Screw caps with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).The filling funnel made of PP has an integrated stopcock. The stopcock with grip is opened by turning the grip and the grip position shows if the stopcock is closed. The automatic stopcock is opened by pushing the grip and closes automatically if the grip is loosened.Scope of supply:Filling funnel (automatic stopcock/ with grip), fittings (UNF 1/4“), blind fitting (UNF 1/4“), hose olive (NPT 1/8")
Screw caps with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).Scope of supply:Fittings (UNF 1/4“), blind fittings (UNF 1/4“), hose olive (NPT 1/8")
Screw caps with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (notincluded in the scope of supply).Scope of supply: fittings (UNF 1/4“), blind fittings (UNF 1/4“), hose olive (NPT 1/8")
Screw cap with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).The Waste Caps are supplied with a permanently mounted cable (400 mm length) to connect the b.safe display for level control. The red indicator pin on the Waste Caps enables visual monitoring of the fill level.Scope of supply: fittings (UNF 1/4“), blind fittings (UNF 1/4“), hose olive (NPT 1/8")
Screw caps with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).The filling funnel made of PP has an integrated stopcock. The stopcock with grip is opened by turning the grip and the grip position shows if the stopcock is closed. The automatic stopcock is opened by pushing the grip and closes automatically if the grip is loosened.Scope of supply:Filling funnel (automatic stopcock/ with grip), fittings (UNF 1/4“), hose olive (NPT 1/8")
Screw cap with free movable insert made of PTFE. Depending on the version, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).The Waste Caps are supplied with a permanently mounted cable (400 mm length) to connect the b.safe display for level control. The red pin on the Waste Caps enables visual monitoring of the fill level.Scope of supply: fittings (UNF 1/4“), blind fittings (UNF 1/4“)
Screw caps, with free movable insert made of PTFE, for connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with I.D. 5.5 to 8 mm. A b.safe exhaust air filter can be screwed into the thread GL 14 (not included in the scope of supply).The filling funnel made of PP has an integrated stopcock. The automatic stopcock is opened by pushing the grip and closes automatically if the grip is loosened.Scope of supply: Filling funnel (automatic stopcock), fittings (UNF 1/4“), blind fitting (UNF 1/4“), hose olive (NPT 1/8")