Connection cable for pH electrodes with plug head connection to plugs as indicated.
Gas and ion selective electrode for determination of ammonia content in aqueous solutions. For rapid and precise measurement of ammonia.Scope of supply: Waterproof BNC connector, 1 m cable, 20 loose membranes, preassembled outer body and membrane cap, 2 x 60 ml bottles of electrode filling solution, spout cap, tweezers
In addition to the immersion stirrer, the attachable stand can hold three additional measuring probes. The adjustable stops prevent damage of probe and beaker. Pillar made of anodised aluminium, carriage and base made of polyamide 12 glass-reinforced.With integrated cable ductStroke of the carriage 190 mmClamping options: 2 x 12 mm, 1 x 4 to 14 mm, 1 x 6 to 16 mmMounting directly on the meterDimensions (W x D x H): 130 x 145 x 300 mm
Guarantee of accuracyCertificate including the actual value and expiry dateCertified traceable to primary SRM from NIST/PTBResistant to microbesConvenient plastic bottle with built-in calibration compartmentEconomical, since less buffer is used per calibrationCertified pH value of one for the pH measurement accredited DKD laboratory
Sealed sachets in boxes as indicated. For single use only. Packaging ensures that buffer solution is always fresh, has not been used before and is not contaminated.
Sealed sachets in boxes as indicated. For single use only. Packaging ensures that buffer solution is always fresh, has not been used before and is not contaminated.
Guarantee of accuracyDKD certificate including the actual value and expiry dateCertified traceable to primary SRM from NIST/PTBResistant to microbesConvenient 500 ml plastic bottle with built-in calibration compartmentEconomical, since less buffer is used per calibrationCertified pH value of one for the pH measurement accredited DKD laboratory
According to DIN 19 266. Values stated at 25°C. To be delivered in DURAN® glass bottles. Hot steam sterilized. Accuracy ±0.012pH. Comes with individual batch number and manufacturer certificate.
For BlueLine pH electrodes, ScienceLine, IoLine and TopLine.Cable length: 1 m coaxial cable.
Supplied in box with three 250 ml bottles of pH 4.01, 6.87, 9.18 buffer solutions, pepsin cleaning solution and KCl filling solution 3 mol/l.
Disposable bags for effective calibration. Traceability according to NIST. ORP + 468 mV (± 5 mV) at 25 °C.
Calibration standards with 10 ml bottle contents each for calibration points at pH 4.01, 7.00 and 10.01.
Certified reference material according to ISO 17034. The uncertainty of measurement of ±0.01 pH was tested at 20 °C. Supplied with detailed certification report which includes traceability to NIST.
Certified reference material according to ISO 17034. The uncertainty of measurement of ±0.01 pH was tested at 25 °C. Supplied with detailed certification report which includes traceability to NIST.
Pepsin HCl solution for cleaning and maintenance of ph electrodes. Removes protein deposits from diaphragms, helping to maintain electrode performance.
Cleaning solution for the removal of protein deposits. Ideal for regular maintenance of pH electrodes.
DMi140-SC: Combined platinum ring redox electrode. For titrations with a change of the pH value, e.g. oxidation with potassium permanganate, copper determination with iodine, back titration with thiosulfate. With S12 screw cap and ARGENTHAL™ reference system. Plug & Play functionality.DMi141-SC: Combined silver ring electrode for argentometric titrations, determination of halides, sulfides and mercaptanes in aqueous media. Also suitable for determination of salt and silver content. With S12 screw cap and ARGENTHAL™ reference system. Plug & Play functionality.DM143-SC: Double pin platinum electrode for electrochemical titrations, e.g. water determination acc. to Karl Fischer, bromine number determination and sulfur dioxide determination in aqueous media. With S7 screw cap and ARGENTHAL™ reference system.DMi144-SC: Combined platinum ring redox electrode. For titrations with a change of the pH value, especially designed for COD determination with the Rondo 20 COD rack. With Plug & Play functionality and ARGENTHAL™ reference system.DMi145-SC: Combined silver ring electrode for argentometric titrations, determination of halides, sulfides and mercaptanes in aqueous media. Also suitable for determination of salt and silver content. With Plug & Play functionality and ARGENTHAL™ reference system.DMi148-SC: Combined silver ring electrode for argentometric titrations without a change of the pH value. For determination of halides, cyanides, sulfides and mercaptanes in mineral oil and bioethanol.
Redox combination electrodes for measuring the oxidation/reduction potential in aqueous solutions. The signal is generated on the surface of the indicator electrode by an electron exchange with the oxidation/reduction system of the measured medium. Without temperature sensor. With Safelock™ end ring for easy refilling of the reference electrolyte and complete sealing in closed position. For use with a wide variety of measuring instruments.InLab® Redox: For general purpose. With platinum ring indicator electrodeInLab® Redox Flow: For emulsions, wastewater analysis and general purpose. With movable ground joint junction and platinum ring indicator electrodeInLab® Redox L: For large samples. With platinum ring indicator electrodeInLab® Redox Au: Combined redox electrode with gold ring indicator electrodeInLab® Redox Ag: Combined redox electrode with silver ring indicator electrodeInLab® Redox Micro: For small samples. With platinum ring indicator electrodePlease order connection cable separately.
Cable for connecting InLab®-DES electrodes. With ALTW 4PIN connector.