Tabletop autoclaves CertoClav EL

Product information "Tabletop autoclaves CertoClav EL"

The vertical laboratory autoclave is suitable for sterilisation of unpackaged solids without hollow bodies, liquids, bottles, instruments, synthetic materials, food preservation, culture media preparation and waste. A precision thermometer, a control valve, and a precision manometer with drag indicator provide precise processes and accurate results for all applications. The autoclave is available in two versions, each with two temperature levels. These temperature settings are controlled via the control valve on the lid. These valves are not interchangeable, because the thermostat of the device is harmonized with and calibrated to the respective valve.

  • Robust construction

  • Thermostat controlled

  • High heating power

  • Venting by flow procedure

  • Heating integrated in the base


Scope of supply: Autoclave, instrument tray, power cable

Dimensions internal (Ø x H): 240 x 260 mm
Ext. depth: 275 mm
Ext. height: 505 mm
Ext. width: 395 mm
External dimensions (WxDxH): 395 x 275 x 505 mm
Heating capacity: 1900 W
Height int.: 260 mm
Int. Ø: 240 mm
Manufacturer Article Number: 8501312
Material interior: Aluminium
Max. pressure: 2.7 bar
Max. voltage: 230 V
Nominal capacity: 12 l
Power supply: 230 V, 50/60 Hz
Power supply frequency: 50/60 Hz
Temperature levels: 125/140 °C
Type: EL 12
Type of auxiliary energy: Mains connection
Weight: 6.2 kg
Skip product gallery

Other customers also bought

Tabletop autoclaves CertoClav MultiControl
Tabletop autoclaves CertoClav MultiControl

The PT100 sensor-controlled, vertical laboratory autoclave is suitable for extended/ long- term cycles, material tests, HAST test, Pressure Cooker Test, ICP-TM 650, culture media preparation, sterilisation of waste, hazardous biological substances (S2), unpackaged solids without hollow bodies, liquids, bottles, instruments, synthetic materials and rubber.Without connecting a PC, the control unit can only be used to set programs that include just one time and one temperature step. For programs that include several time and temperature steps, the PC software professional version is required.Microprocessor-controlledVenting by fractional flow procedureElectronic process controlProgrammable from 1 minute to 30 days and from room temperature to 140 °CControl unit with LCD displayUSB portPrinter port (RS232) for printing sterilisation protocolsHeating integrated in the baseScope of supply: Autoclave, MC2 control unit, instrument tray, power cable, PC software basic version