Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond
                                            
                            Content:
                        
                    
                                            
                            1 
                        
                    
                    
                
                            
                        
                                            
                            Product number:
                        
                    
                                            
                        
                            9774710
                        
                                    
                        Product information "Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond"
                        Portavo 902 Cond
Portavo 904 Cond
as Portavo 902 Cond, additionally with:
Portavo 904 X Cond
as Portavo 904 Cond, additionally with:
                    
                
                                                                - The basic version for mobile conductivity measurement
- Robust, intuitive portable device for routine daily measurements in laboratories and processes
- A sensor quiver protects the sensor from drying out or being damaged in daily use
- The high-performance polymer housing ensures low water absorption and high impact resistance
- Over 1000 hours of measurement with a single set of batteries (4 x AA)
- Memosens sensors and analog sensors can be used on the same device
- The mineral glass display is perfectly readable even after years
Portavo 904 Cond
as Portavo 902 Cond, additionally with:
- Li-ion battery
- Data logger with 5,000 values
- Micro USB port and Paraly SW 112 software
Portavo 904 X Cond
as Portavo 904 Cond, additionally with:
- Conductivity measurement with ATEX approval for measurements up to Zone 0/1. Ideal for applications in the process industry. For the first time, Portavo enables direct on-site testing of process measuring points.
- The new MemoLog function allows the user to log calibration data from various Memosens measuring points
| Specifications | |
| Measuring range (Accuracy): | 0.001 µS/cm (c0.05 cm-1) 0.01 µS/cm (c=0.05 ... 0.2 cm-1) 0.1 µS/cm (c0.2 cm-1) | 
| TDS: Salinity: | 0 ... 1999 mg/l 0.0 ... 45.0 g/kg | 
| Resistivity: Concentration: | 00.00 ... 99.99 MO x cm 0.00 ... 9.99 (w/w) % | 
| Conductivity input, analog: | Multi-contact for 2-/4-electrode sensors with integrated temp detector | 
| Measuring ranges Sensor SE 202: Sensor SE 204: | 0.01 ... 200 µS/cm 1 µS/cm ... 500 mS/cm | 
| 2-electrode sensors: 4-electrode sensors: | 0.1 µS x c ... 200 mS x c 0.1 µS x c ... 1000 mS x c | 
| Temperature input: | 2 x 4 mm diam. for integrated or separate temperature detector | 
| Messbereich mit NTC 30 kO: Messbereich mit Pt 1000: | -20 ... 120 °C -40 ... 250 °C | 
| Conductivity input, Memosens: | M8 socket, 4 pins, for Memosens lab cable | 
| Measuring range sensor SE 215 MS: | 10 µS/cm ... 20 mS/cm | 
| Conductivity input | |
| Temperature compensation: | Linear 0 ... 20 %/K, reference temperature adjustable | 
| nLF: | 0 ... 120 °C | 
| Power supply: Protection class acc. to DIN EN 60529: | 4 x AA IP66/67 with pressure compensation | 
| Manufacturer Article Number: | 902 COND | 
|---|---|
| Type: | 902 Cond | 