Filter products
                                –
                            
                        
                                                    
                                            - General laboratory consumables
- Occupational safety, Security
- Analytical measurement and testing
- Stirring, Shaking, Mixing
- Sample preparation
- Distillation, separation, filtration
- Heating and cooling technology
- Liquid Handling
- Vacuum technology, Drying, Dry storage
- Optical instruments and Microscopes
- Cleaning and sterilisation
- Environmental-, soil-, water-, food analysis
- Life Sciences
- Chromatography
- Cleanroom
- About Us
                                                                                        
                                                                                            
                                    Temperature-humidity data logger Traceable®
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Data logger with integrated sensors for monitoring temperature and relative humidity. The data logger can be connected to a Bluetooth®-enabled mobile device via the Bluetooth® interface. With the TraceableGO™ app (free of charge) or the TraceableLIVE™ cloud service (chargeable, registration required), measured values can be exported as a PDF, sent by e-mail, and stored on a mobile end device.Large LCD displayDisplay changes between temperature and humidity every 5 secondsSwitchable °C / °FLimit values and logging interval adjustable via TraceableGO™ or TraceableLIVE™ appStorage of up to 90 different alarm messagesNIST-traceable certificate includedScope of supply: Temperature-humidity data logger, batteries, NIST-traceable calibration certificateTemperature range:-20 ... 70 °CAccuracy:±0.4 °C (-10 ... 70 °C), ±0.5 °C remaining rangeResolution:0.1 °CHumidity range:0 ... 95 % RHAccuracy:±3 % RH (5 ... 75 % RH), ±5 % RH remaining rangeResolution:0.1 % RHLogging interval:1 min ... 12 hMemory:65536 measured valuesPower supply:2 x AAA
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Mini temperature/pressure data logger EBI 11-TP210
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The temperature/pressure data logger is specifically designed to measure temperature and pressure inside a bottle for pasteurization control.Space-saving stainless steel housingWireless measurementM5 threadTemperature-compensated pressure measurement over the complete measuring rangePT1000 temperature probe and piezoresistive pressure sensorMemory for up to 2 x 7500 measured valuesFactory calibration certificate: 0 °C, 60 °C, and 134 °C / 100 mbar, 3100 mbar, and 6000 mbar at 25 °C, 3100 mbar at 134 °CScope of supply: Temperature/pressure data logger
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature/pressure data logger EBI 12-TP237
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Robust, sterilizable temperature/pressure data logger for process validation and routine or batch control in the washer-disinfector and steam sterilizer.Hose connection and M10x1 internal threadWireless measurementReal-time data transmissionPT1000 temperature probe and piezoresistive pressure sensorTemperature probe (Ø 1.95 mm) rigid, axialNeedle length 20 mmMemory for up to 2 x 33440 measured valuesFactory calibration certificate: 0 °C, 60 °C, and 134 °C / 100 mbar, and 3100 mbar at 25 °C, 3100 mbar at 134 °CScope of supply: Temperature/pressure data logger
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature / Humidity data logger testo 184 H1
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The Multiparameter data loggers testo 184 H1 / 184 G1 monitor every step of the cold chain in the transport of sensitive goods. Direkt control of whether the configured limit values have been adhered to at the destination. Conneting the logger to a PC is sufficient to generate a PDF report. Easy handling due to the stored files for configutration, acceptance test certificate and instruction manual.Clear alarm indicationEasy configuration without software installationConvenient readout due to automatic PDF reportConformity to GxP, 21 CFR Part 11, HACCP and EN 12830SpecificationsTemperatureMeasuring range:-20 ... +70 °CAccuracy:0.1 °CPrecision:±0.5 °C (0 ... +70 °C)
±0.8 °C (-20 ... 0 °C)HumidityMeasuring range:0 ... 100 % r.h.Resolution:0.1 % r.h.Accuracy:±2 % r.h. (20 ... 80 % r.h.)
±3 % r.h. (20 ... 80 % r.h.)Measuring rate:1 min ... 24 hHousing:ABSPower supply:incl. 1 x CR2450, 3 VDimensions (W x D x H):40 x 12 x 97 mmWeight:44 gIP code:IP 30SpecificationsBattery life:500 days ( at +25 °C, 15 min measuring rate)Memory:64000 values
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Standard PDF data logger EBI 300 TH
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    PDF data logger with external humidity and temperature sensor TPH 400, internal temperature sensor can also be used.For temperature monitoring related to HACCP/IFS issues or other perishable goodsTransportation of fresh, cool and deep cool productsMonitoring of fridges and deep freezersEvaluation without software, PDF are automatically generatedMinimise training, user errors and IT costs using EBI 300's simple, easy to use design and standard softwareEnsure data integrity since no data manipulation is possibleEN 12830, ATP, VO(EG) 37/2005 CompliantFactory calibration certificate includedProgrammable via the free online configurator at www.ebi300.comNo separate interface for programming and readingMemory: 40000 samplesMeasuring modes: Start/Stop, endless loop, start with buttonAlarms: 2 values, high and low limits
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    High precision PDF data logger EBI 310 TH
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    PDF data logger with external humidity and temperature sensor TPH 500, internal temperature sensor can be used additionally. Monitoring the relative humidity in storage and transport. Compared to the EBI 300, the EBI 310 is characterized by shorter measuring intervals and higher storage capacity.Automatic PDF-report creation with temperature/time valuesTransport of drugs, inoculants, blood products and primary productsTransport of all temperature sensitive productsStorage of reference samples in refrigerators and deep-freezers"Traffic light principle" by limit exceededIQ/OQ procedures through standardized software and standard reporting process possibleGMP, pharmaceutical law compliant; EN 12830, ATP, VO (EG) 37/205 compliant, 21 CFR Part 11 conform (Winlog.basic)Programmable via the free online configurator at www.ebi300.comMeasuring modes: Start/Stop, endless loop, start with buttonAlarms: 5 values
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    WiFi Temperature-humidity logger testo Saveris 2-H2
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The WiFi data logger is ideal for monitoring temperature and relative humidity in rooms. Measurement data is sent to the testo Cloud (online data storage) via wireless LAN and can be accessed and evaluated on all internet-enabled end devices. The testo Cloud Basic package can be accessed free of charge.Internal data memory up to 10000 measured values per channelLimit values adjustable via testo-CloudE-mail notification when limit values are exceededCurrent measured values can be read on the displayMicro USB interface1 connection for external temperature and humidity probesAn external temperature and humidity probe is required to operate the testo Saveris 2-H2. Please order separately.Scope of supply: WiFi Temperature-humidity logger, testo-Cloud access (basic functionality), micro USB cable, wall bracket, batteries, calibration protocolSensor type:NTCMeasuring cycle:15 min ... 24 hCommunication cycle:15 min ... 24 hMemory:10000 measured values per channelDimensions:95 x 75 x 30.5 mmWeight:240 gPower supply:4 x AA AlMn Mignon batteriesIP code:IP54
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Stainless steel sintered filter AH 300
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The stainless steel sintered filter increases the protection class to IP 40. The stainless steel used increases the mechanical protection and is highly resistant to corrosion, even in high-temperature applications.
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    WiFi Temperature-humidity logger testo Saveris 2-H1
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The WiFi data logger is ideal for monitoring temperature and relative humidity in rooms. Measurement data is sent to the testo Cloud (online data storage) via wireless LAN and can be accessed and evaluated on all internet-enabled end devices. The testo Cloud Basic package can be accessed free of charge.Internal data memory up to 10000 measured values per channelLimit values adjustable via testo-CloudE-mail notification when limit values are exceededCurrent measured values can be read on the displayMicro USB interfaceWith internal temperature and humidity probeScope of supply: WiFi Temperature-humidity logger, testo-Cloud access (basic functionality), micro USB cable, wall bracket, batteries, calibration protocolSensor type:NTC internalTemperature range:-30 ... 50 °CAccuracy temperature:±0.5 °CHumidity range:0 ... 100 % rHAccuracy humidity:±2 % rHMeasuring cycle:15 min ... 24 hCommunication cycle:15 min ... 24 hMemory:10000 measured values per channelDimensions:115 x 82 x 31 mmWeight:250 gPower supply:4 x AA AlMn Mignon batteriesIP code:IP30
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature / Humidity data logger LOG 210
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    PDF-data logger with displayMemory size: 100.000 measurementsUsable without software (default settings) (5-minute-interval, without alarm settings)Automatic PDF creationMovement sensor for shock recording e.g.: door or windows closingFree adjustable recording interval: 10 seconds to 24 hoursMax-Min-Display memory (resettable)Time marking functions for measuring resultsBattery lifetime approx. 4 years (recording interval >15 minutes)Status- and Alarm-LEDsIncludes wall mountFree software LogConnect, for configuring (alarms, interval, changing display settings) or LogGraph2 for comfortable graphical and tabular display of measured values, incl. drag and zoom. Software is available as download.SpecificationsTemperatureMeasuring range:-40 to +70 °CAccuracy:0.1 °CPrecision:±0.5 °C (0 to +60 °C), otherwise ±1.0 °CHumidityMeasuring range:0 to 100 % R.H.Resolution:0.1% R.H.Accuracy:±3 % R.H. (40 to 60 %), ±3.5 % R.H. (20 to 40 % and 60 to 80 %), otherwise ±5 % R.H.Interface:
Housing:USB (integr.)
Plastic (ABS)Battery:1 x 3,6 Volt Lithium ½ AADimensions:91.5 x 42 x 20 mmWeight:approx. 70 g
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature / Humidity / Pressure data logger LOG 220
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    PDF-data logger with displayMemory size: 60000 measurementsUsable without software (default settings) (5-minute-interval, without alarm settings)Automatic PDF creationFree adjustable recording interval (10 seconds to 24 hoursMax-Min-Display memory (resettable)Time marking functions for measuring resultsMovement sensor for shock recording e.g.: door or windows closingBattery lifetime approx. 4 years (recording interval >15 minutes)Includes wall mountStatus- and Alarm-LEDsFree software LogConnect, for configuring (alarms, interval, changing display settings) or LogGraph2 for comfortable graphical and tabular display of measured values, incl. drag and zoom. Software is available as download.SpecificationsTemperatureMeasuring range:-40 to +70 °CAccuracy:0.1 °CPrecision:±0.5 °C (0 to +60 °C), otherwise ±1.0 °CHumidityMeasuring range:0 to 100 % R.H.Resolution:0.1% R.H.Accuracy:±3 % R.H. (40 to 60 %), ±3.5 % R.H. (20 to 40 % and 60 to 80 %), otherwise ±5 % R.H.PressureMeasuring range:300 to1100 hPaAccuracy:0.1 hPaPrecision:±1 hPa (900 to 1100 hPa), otherwise 0.5 % of end valueInterface:
Housing:
Power supply:USB (integr.)
Plastic (ABS)
1 x 3,6 Volt Lithium ½ AADimensions:
Weight:91.5 x 42 x 20 mm
70 g
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature / Humidity / Shock data logger testo 184 G1
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    SpecificationsBattery life:500 days ( at +25 °C, 15 min measuring rate)Measuring range shock:0 ... 27 gResolution:0,1 gAccuracy:±0,1 g + 5 % of measured valueMemory:64000 values + 1000 values (shock)
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    PTFE filter AH 100
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The PTFE filter makes humidity probes dust-tight (IP 60) and thus prevents affecting the humidity measurement.
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature and humidity logger LOG210 TC
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Data logger with motion sensor, integrated USB interface for automatic PDF output and wall mount. For measurement and recording of temperature and humidity and 2 connections for external type K thermocouples.Freely adjustable recording interval from 10 seconds to 24 hoursMin- and Max-values can be reset in the displayTime marking function ("Time Marker") during data recordingWith movement sensor for shock recordingMemory for approx. 60000 measurementsAutomatic output as PDF file, device can also be used without softwareNo driver installation neededStatus and alarm LEDs, with buzzerDisplay can be switched offBattery life > 4 years at > 15 min measuring interval (free of charge)USB interface for data transferSoftware available for download on the manufacturer's websiteTemperature and humidity sensors are available separately.Scope of supply: Data logger, 2 thermocouples type K (1 m length), wall mount, battery, USB cover, screws and dowelsSpecificationsTemperature range internal:
Temperature accuracy internal:-40 ... 70 °C
±0.5 °C (0 ... 60 °C), otherwise ±1 °CTemperature range external:
Temperature accuracy external:-150 ... 1370 °C
±0.5 °C or 0.5 % (the greater value applies)Temperature resolution:0,1 °CHumidity range:
Humidity accuracy:0 ... 100 % r.H.
±3 % r.H. (40 ... 60 % r.H.), ±3,5 % r.H., (20 ... 40 and 60 ... 80 % r.H.), otherwise ±5 % r.H.Humidity resolution:0.1 % r.H.Housing:ABSDimensions (W x D x H):42 x 20 x 91.5 mmWeight:70 gPower supply:1/2 AA 3.6 V
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    External temperature probe for data logger LOG200E/LOG220E
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Pt 100 temperature probe with 1/3 DIN sensor and cable.
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature, humidity, pressure and CO2 logger LOG220E
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Data logger for temperature, humidity and pressure recording with an external connection for a CO2 sensor or humidity, pressure and temperature sensor.Freely adjustable recording interval from 10 seconds to 24 hoursMin- and Max-values can be reset in the displayTime marking function ("Time Marker") during data recordingWith movement sensor for shock recordingMemory for approx. 60000 measurementsAutomatic output as PDF file, device can also be used without softwareNo driver installation neededStatus and alarm LEDs, with buzzerDisplay can be switched offBattery life > 4 years at > 15 min measuring intervalUSB interface for data transferSoftware available for download on the manufacturer's website (free of charge)Temperature, pressure humidity and CO2 sensors are available separately.Scope of supply: Data logger, wall mount, battery, USB cover, screws and dowelsSpecificationsTemperature range internal:
Temperature accuracy internal:-40 ... 70 °C
±0.5 °C (0 ... 60 °C), otherwise ±1 °CTemperature range external:
Temperature accuracy external:-200 ... 850 °C
±0.2 °C or 0.3 % (the greater value applies)Temperature resolution:0.1 °CHumidity range:
Humidity accuracy:0 ... 100 % r.H.
±3% r.H. (40 ... 60 % r.H.), ±3,5 % r.H. (20 ... 40 % and 60 ... 80 % r.H.), otherwise ±5 % r.H.Humidity resolution:0,1 %Pressure range:
Pressure accuracy:300 ... 1100 hPa
±1 hPa (900 ... 1100 hPa), otherwise 0.5 % of end valuePressure resolution:0.1 hPaHousing:ABSDimensions (W x D x H):42 x 20 x 91.5 mmWeight:70 gPower supply:1/2 AA 3,6 V
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    WiFi data logger testo 160 IAQ
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The WiFi data logger is ideal for monitoring indoor air. In mains operation, coloured LEDs indicate the air quality according to the traffic light principle.Monitoring of temperature, humidity, atmospheric pressure and CO2CO2 limit values can be individually set in the testo CloudMeasurement value transfer via WLAN to the cloud storage: data can be retrieved at any time on PC or mobile devicesE-mail notification when limit values are exceededCompact designLCD displayUSB interfaceScope of supply: WiFi data logger testo 160 IAQ, USB mains unit, 4 x AA Batteries, Wall bracket, QR code sticker, Calibration protocol, Short instructions, free Cloud access (Basic functionality)Temperature range:0 ... 50 °CAccuracy temperature:± 0.5 °CResolution temperature:0.1 °CHumidity range:0 ... 100 % rHAccuracy humidity:± 2.0 % (20 ... 80 % rH), ± 3.0 % (20 and 80 % rH)Resolution humidity:0.1 % rHCO2 range:0 ... 5000 ppmAccuracy CO2:± 50 ppm + 3 % of mv at 25 °C, ± 100 ppm + 3 % of mv at 25 °C (without external power supply)Resolution CO2:1 ppmMemory:32000 measuring valuesMeasuring rate:15 min ... 24 hRadio range:100 mDimensions (L x W x H):117 x 82 x 32 mmWeight:269 gPower supply:4 x AA 1.5 V, USB mains unitIP code:IP 20
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Mini temperature humidity logger testo 174 H BT
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The mini temperature humidity logger is used to monitor temperature and humidity-sensitive goods and to check the indoor climate. The device can store up to 16000 measured values and guarantees reliable protection against data loss thanks to automatic data backup in the event of an empty battery or battery change. Thanks to the Bluetooth® connection, data can be read out directly at the measuring point up to 30 m away. The free testo Smart App enables simple and intuitive configuration as well as analysis of the measurement data. PDF reports and Excel exports can also be created in the app and supplemented with photos and comments. Certified according to HACCP.Scope of supply: Mini temperature humidity logger, wall bracket, batteries, test report
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Mini temperature humidity logger testo 174 H
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    The mini temperature humidity logger is used to monitor temperature and humidity-sensitive goods and to check the indoor climate. The device can store up to 16000 measured values and guarantees reliable protection against data loss thanks to automatic data backup in the event of an empty battery or battery change. Data can be read out quickly and easily via the USB-C interfaces without a separate readout station. The free ComSoft Basic software enables quick configuration and simple data analysis. It offers Excel export and PDF report generation, ensuring professional documentation. Certified according to HACCP.Scope of supply: Mini temperature humidity logger, wall bracket, batteries, USB 2.0 data transfer cable, test report
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Wireless temperature-humidity data logger EBI 25-TH
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Wireless temperature and humidity data logger. With internal temperature sensor and external humidity sensor.Readout via wireless interfaceReplaceable batteryLCD displayMemory for 288 values per channelThe IF 400 base station and the Winlog.web/Winlog.wave PC software are required for programming and evaluating the EBI 25-TH data logger.Scope of supply: Temperature-humidity data logger, operating manual
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Data logger LOG32THP
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Temperature-humidity-pressure logger with integrated USB-interface and automatic PDF-creation.Incl. calibration certificateMemory for 3 x 60000 readingsUseable without software (pre-programmed reading interval of 5 minutes)Automatic output as PDF file (no drivers required)Free adjustable recording interval from 30 seconds up to 24 hours (via Software Log Connect)Battery life > 2 years (with recording interval >15 minutes)Status and alarm LEDsWith wall mount, fixing screws, an battery (1/2 AA, 3.6 V)
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature / Humidity data logger LOG 110
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Large display for actual value, battery status display, easy to use software.Perfect designed instrument for transportation or storage after HACCP.Quality surveillance in laboratories, at the production or in the storageAmbient conditions in manufacturing facilitiesAmbient conditions in power plantsMonitoring of fridges for the pharma industryMemory for 60000 data setsPlease order Software with USB-Cabel separately (9.726 413).SpecificationsTemperatureMeasuring range int.:
Measuring range ext.:-30 ... 70 °C
-50 ... 125 °CAccuracy:0.1 °CPrecision:Int.: ±0.5 °C (-10 ... 40 °C), otherwise ±0.7 °C
Ext.: ±0.5 °C (0 ... 40 °C), otherwise ±0.7 °CHumidityMeasuring range:0 ... 99 % r.H.Resolution:0.1% r.H.Accuracy:±3 % r.H.Housing:Plastic (ABS)Power supply:1 x CR2032 3 VDimensions:88 x 55 x 20 mmWeight:95 g (incl. packaging)Alarm function:Alarm for too low or too high temperature and/or humidity values
Calibration reminder
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature-humidity logger LOG32TH
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Data logger for monitoring and recording temperature and humidity during the storage and transportation of sensitive products. Measurement data can be transferred to a PC via the integrated USB interface, and evaluated and documented using the free LOG CONNECT software.Incl. calibration certificateMemory for 2 x 60000 data recordsUsable without software, with pre-programmed reading interval of 5 minutesFreely adjustable recording interval from 30 seconds to 24 hoursAutomatic output as PDF file (logger is recognized like USB memory stick)Battery life >2 years (with recording interval >5 minutes)Status and alarm LEDsIncl. wall mount and battery (1/2 AA, 3.6 V)Application profile:Quality monitoring in the laboratory, during production or in the warehouseAmbient conditions in production facilitiesMonitoring storage and transport conditions in accordance with HACCPAmbient conditions in power plantsMonitoring of refrigerators for pharmaceuticals
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature/Humidity data logger EBI 20-TH1
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Applications:Reliable temperature and temperature/humidity recordingTransportStorage monitoringRefrigeration areas and coldroomsFeatures:Excellent price/performance ratioVisual AlarmMax./min. values on displayStores 40000 readings, can be read off at any timeReplaceable batteryMeasuring mode: immediate loop measurement, measurement from starting point, start immediately until memory full, start/stop measuring, start when button pressedScope of supply: Temperature/Humidity logger
                                
                            
                                
    
                                                                    
                            
            
                                                                
                                                                                        
                                                                                            
                                    Temperature/Humidity data logger EBI 20-TH1-Set
                                
                            
                                                            
                                    
                                                                            
                                
                            
                                                            
                                    
                                    Applications:Reliable temperature and temperature/humidity recordingTransportStorage monitoringRefrigeration areas and coldroomsFeatures:Excellent price/performance ratioVisual AlarmMax./min. values on displayStores 40000 readings, can be read off at any timeReplaceable batteryMeasuring mode: immediate loop measurement, measurement from starting point, start immediately until memory full, start/stop measuring, start when button pressedScope of supply: Temperature/Humidity logger, evaluation software, interface
                                
                            
                                
    
                                                                    
                            
            
                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                 
                                                                                                                                                                                                                                                                                